Product Description
Key Features
• Minimise the effects of power fluctuations and surge protection
• Intelligent Slot to accommodate an optional SNMP card
• Battery is easily hot swappable and user replaceable
• Allows for orderly shutdown without software
• 6 Australian sockets and 2 x 10 Amp IEC outlets
• Free NetGuard software provides complete power monitoring via USB
PowerShield Defender RackMount 800VA
RACK UPS. The Defender Rackmount expands the successful Defender Range by building the popular features into a Rack Mount NAS UPS perfect for shallow, wall mounted Comms cabinets.
This versatile UPS uses Automatic Voltage Regulation (AVR) to minimise the effects of fluctuations in input voltage, protecting your valuable equipment from power line disturbances whilst also incorporating the best surge protection in its class.
Visit the PowerShield UPS Sizing Guide. which will help you select the correct UPS for your power protection needs.
Features
- Modern, stylish LCD display indicates voltage in/out, amount of load and remaining capacity
- Plug and play on any computer or NAS drive
- Allows for orderly shutdown without software
- The AVR automatically bucks/boosts unstable fluctuating utility voltages, bringing them within 10% of nominal voltage range and thereby protecting valuable equipment
- Battery is easily hot swappable and user replaceable
- After an extended power outage the UPS will turn back on and resume equipment functionality once power has returned
- The plugged in UPS will continue to charge internal batteries whether the unit is on or off
- Comes standard with 6 Australian sockets and 2 IEC outlets. Of the 6 Australian outlets, 4 can be used with plug packs
- The UPS can turn on equipment when it is off, simply by connecting equipment and turning the UPS on.
- The free, downloadable NetGuard software provides complete power monitoring
Specifications
DEFENDER RACKMOUNT 800VA UPS |
|
Capacity | 800VA / 480W |
Topology | Line Interative |
INPUT |
|
Voltage | 240Vac (Nominal) |
Voltage Range | 177-290Vac |
Frequency Range | 50/60Hz (auto sensing) |
OUTPUT |
|
Output Voltage | 240Vac ± 10% |
Frequency Range (Batt. Mode) | 50Hz or 60Hz ±1Hz |
Transfer Time | 6ms (Typical) |
Waveform (Batt. Mode) | Simulated Sine Wave |
Australian Outlets - UPS & Surge Protection | 2x 10 Amp IEC Sockets, 6 x Australian Sockets |
BATTERY |
|
Battery Type & Number | 12V / 9AH (x1) |
Typical Recharge Time | 4- 6 hours recover to 90% capacity |
Backup Time (50% Load) | 8 min |
PROTECTION |
|
Full Protection | Overload, discharge and overcharge protection |
Surge Protection | 312Joules / 6500Amps |
COMMUNICATIONS & MANAGEMENT |
|
Interface | USB as standard, Intelligent slot for PSSNMP |
Software | NetGuard® supports - Windows®, Linux, Unix and Mac (Free Download) |
HID | Supports Windows, Apple, Linux, NAS and various industrial controllers |
LCD Alarm | AC Mode, Battery Mode, Low Battery (Batt. Mode), Fault, Overload |
Audible Alarm | Battery Mode, Low Battery (Batt. Mode), Fault, Overload |
PHYSICAL |
|
Dimension L x W x H (mm) | 230 x 438 x 86 |
Net Weight (kgs) | 7.7 |
OPERATING ENVIRONMENT |
|
Temperature | 0-40°C |
Humidity | 0-90% RH (non-condensing) |
Noise Level | Less than 5dBA @ 1 meter (no fan) |
COMPLIANCE |
|
Safety/EMC | EN62040-1 -1 2003, IEC60950-1 : 2001, EN62040-2 2006 |
RoHS | Directive 2011/65/EU |
* Specifications are subject to change without notice.
What's In The Box
- PSDR800 rackmount UPS
- USB Communication cable
- Rackmount Ears
- User’s Manual